Calibration Report Analog
A Calibration Report Analog is a instance of a Analog Device on the calibration report containing the information regarding the device calibration.
Attributes
- As Found - Live Reading - The live reading of the device when left.
- As Left - Live Reading - The live reading of the device when found.
- Calibration Range - Low - The low range of the analog device calibration. This field will be automatically populated from the device configuration.
- Calibration Range - High - The high range of the analog device calibration. This field will be automatically populated from the device configuration.
- Public Notes - Available for any notes related to the device calibration. Notes are public and visible to all Employees and Clients.
- Calibration Acceptable - The device calibration was completed successfully.
Test data can also be added to the report by clicking the 'Add Test' button. Doing so will display a form to collect test data. Any number of tests can be added to the report.
- Applied - The calibration value applied to the device.
- Rising/Falling - Whether the trip was recorded on rising or falling value.
- Reading as Found - The device reading at the applied value when found.
- Reading as Left - The device reading at the applied value when left.
- Percent Span - The percentage of range that was tested. If left blank this value will be automaticaaly calculated based on the calibration range.
Employee Access
Employee | List View | Detail View | Create New | Edit Existing | Delete | Accessible Device Reports |
---|---|---|---|---|---|---|
Administrator | Yes | Yes | Yes | Yes | Yes | All devices belonging to calibration reports of the company |
Head Office Manager | Yes | Yes | Yes | Yes | Yes | All devices belonging to calibration reports of the company |
Head Office Administrator | Yes | Yes | Yes | Yes | Yes | All devices belonging to calibration reports of the company |
Branch Office Manager | Yes | Yes | Yes | Yes | Yes | All devices belonging to calibration reports of the branch user is associated with |
Branch Office Administrator | Yes | Yes | Yes | Yes | Yes | All devices belonging to calibration reports of the branch user is associated with |
Employee | Yes | Yes | Yes | Yes | Yes | All devices belonging to calibration reports of the branch user is associated with |
Client Access (when service provider enabled)
Client | List View | Detail View | Create New | Edit Existing | Delete | Accessible Device Reports |
---|---|---|---|---|---|---|
Customer Manager | Yes | Yes | No | No | No | All devices belonging to calibration reports of the customer |
Customer Operator | Yes | Yes | No | No | No | All devices belonging to calibration reports of the customer |
Area Manager | Yes | Yes | No | No | No | All devices belonging to calibration reports in permitted areas |
Area Operator | Yes | Yes | No | No | No | All devices belonging to calibration reports in permitted areas |
Location Manager | Yes | Yes | No | No | No | All devices belonging to calibration reports in permitted locations |
Location Operator | Yes | Yes | No | No | No | All devices belonging to calibration reports in permitted locations |
List Views
The Calibration Report Analogs list view is available from the CalibrationReport. Clicking the 'Add Analog Devices' button at the top of the view will display the list view. The list view displays the Analog Devices available at the location for calibration and clicking the tab 'Devices On Report' will display the devices currently on the Calibration Report.
The lists are sorted by device tag and device type (input/output).
Details
The Calibration Report Analog detail view displays a full report of the calibration data recorded during the calibration.